Instruments
| INSTRUMENT | UTILITY | IMAGE |
| Agilent Technologies 6520 Accurate Mass Q-TOF / MassHunter-WindowsXP OS (2009) |
LC-Tof-MS (Q) - Quadrupole MS General application: Fully automated quantitative analysis of drugs and metabolites. |
|
| Waters Micromass Synapt Ion Mobility TOF MassLynx 4.1 DS, WindowsXP OS (2008) |
LC-MS/IMS/MS (QT oa TOF) Tandem Hybrid /MS General application: Automated LC/MS/MS. Accurate mass analysis of complex biological extracts. |
![]() |
| Waters Micromass Quattro Micro API / MassLynx 4.1, WindowsXP OS (2008) |
LC-MS/MS (Q T Q) Tandem Quadrupole MS General application: Automated LC/MS/MS quantification. Drug metabolism studies. Analysis of complex biological extracts. |
|
| Waters Micromass Quattro Premier XE / MassLynx 4.1, WindowsXP OS (2006) |
LC-MS/MS (Q T Q) Tandem Quadrupole MS General application: High sensitivity fully automated quantification and screening. Drug metabolism and interaction studies. Data dependent analysis of complex biological extracts. |
![]() |
| Shimadzu QP2010 / GCMS Solution 2.40, WindowsXP OS (2006) |
GC-MS(Q) - Quadrupole MS General application: Automated quantitative and qualitative analysis. Drugs, metabolites, and endogenous compound studies. Characterization and Identification of synthetic and natural products. |
![]() |
| Thermo LTQ-Orbitrap / Xcalibur 2.0 DS, WindowsXP OS (2006) |
LTQ [FT(OT)] Tandem Hybrid MS/MS General application: Capillary LC/MS/MS of proteolytic digests of simple and complex mixtures. |
![]() |
| Thermo LTQ-FT / Xcalibur 2.0 DS, WindowsXP OS - Michrom MS4B (2004) |
LTQ [FT(ICR)] Tandem Hybrid MS General application: Capillary LC/MS/MS of proteolytic digests of simple and complex mixtures. |
![]() |
| Bruker Autoflex II / Compass 1.0, WindowsXP OS (2004) |
MALDI (TOF) MS - Time of Flight MS General application: Characterization and identification of proteins by peptide mass mapping. PSD and peptide sequencing. |
![]() |
| Bruker APEX Qe 47/ APEX Control 2.0 DS, Windows 2000 OS (2002) |
± ESI Q H [FT(ICR)] MS/MS Fourier transform Tandem Hybrid MS General application: Identification & quantification of sample limited biologic materials by combined high resolution mass accuracy & high sensitivity. |
![]() |
| Agilent Technologies 6460 QQQ / MassHunter-WindowsXP OS (2010) |
LC-MS (Q) - Quadrupole MS General application: Drug metabolism and interaction studies. Data dependent analysis of complex biological extracts. |
![]() |
| AB Sciex API4000 / Analyst 4.2, WindowsXP OS (2006) |
LC-MS/MS (Q T Q) Tandem Quadrupole MS General application: Drug metabolism and interaction studies. Data dependent anlysis of complex biological extracts. |
![]() |
| Varian Unity-Inova 500 (500 MHz) (NMR) |
LC-Tof-MS (Q) - Quadrupole MS General application: Chemical structure elucidation and chemical purity. |
![]() |