The School of Pharmacy Mass Spectrometry Center is home to 11 mass spectrometers and LCs that are available for use by students, staff, faculty and outside users.

High Resolution / High Mass Accuracy Instruments:

Agilent 6520 Accurate Mass QTOF
LC-Tof-MS (QTOF) – Quadrupole MS
General application: Fully automated quantitative analysis of drugs and metabolites.
Agilent_6520_Accurate_Mass_QTOF
Waters Synapt - G1 QTOF
LC-MS/MS (QTOF)
Tandem Quadrupole MS
General application: High sensitivity fully automated quantification and screening. Drug metabolism and interaction studies. Data dependent analysis of complex biological extracts.
Waters_Synapt_G1_QTOF
Waters Synapt - G2 HDX QTOF
LC-MS/MS (QTOF)
Tandem Quadrupole MS
General application: High sensitivity fully automated quantification and screening. Drug metabolism and interaction studies. Data dependent analysis of complex biological exdivacts.
Waters_Synapt_G2_HDX_QTOF
Thermo LTQ-OT
LTQ [FT(OT)]
Tandem Hybrid MS/MS
General application: Capillary LC/MS/MS of proteolytic digests of simple and complex mixtures.
Thermo_LTQ-OT

Triple Quad Instruments:

Agilent 6460 QQQ
LC-MS (QQQ) – Quadrupole MS
General application: Drug metabolism and interaction studies. Data dependent analysis of complex biological extracts.
Agilent_6460_QQQ
Waters Xevo TQ-S-1
LC-MS/MS (QQQ)
Tandem Quadrupole MS
General application: High sensitivity fully automated quantification and screening. Drug metabolism and interaction studies. Data dependent analysis of complex biological extracts.
Waters_Xevo_TQ-S
Waters Xevo TQ-S-2
LC-MS/MS (QQQ)
Tandem Quadrupole MS
General application: High sensitivity fully automated quantification and screening. Drug metabolism and interaction studies. Data dependent analysis of complex biological extracts.
Waters_Xevo_TQ-S
AB/Sciex API4000 Qtrap
LC-MS/MS (Qtrap)
Tandem Quadrupole MS
General application: Drug metabolism and interaction studies. Data dependent analysis of complex biological extracts
ABI4000Qtrap

 

AB/Sciex 6500

 

LC-MS/MS (QQQ)
Tandem Quadrupole MS
General application: High sensitivity fully automated quantification and screening. Quantitative proteomics, drug metabolism and interaction studies.
AB_6500

 

MALDI, GC and UV/Vis Fraction Collector:

Bruker Autoflex II
LC-MS (Q) – Quadrupole MS
General application: Drug metabolism and interaction studies. Data dependent analysis of complex biological extracts.
Bruker_Autoflex_II
SHIMADZU QP2010 GC-MS
GC-MS(Q) – Quadrupole MS
General application: Automated quantitative and qualitative analysis. Drugs, metabolites, and endogenous compound studies. Characterization and Identification of synthetic and natural products.
Shimadzu_QP_2010
UV/Vis DAD With Fraction Collector
1290 Agilent Infinity UPLC Stack
Agilent 1260 Fraction Collector
Agilent DAD UV/Vis Detector